RT Series 5/6/8/10/15/20 kVA (new) - Amplon Family

Product code :


RT Series 5/6/8/10 kVA Single Phase UPS, 15/20 kVA Three Phase UPS

A total solution for reliable power with high availability and performance

The Amplon RT Series 5-20kVA is an online double-conversion UPS that provides best-in-class designs in compact 2U size, high power density, system efficiency, and versatile configurations to fulfill customers' requirements. Unity output power factor maximizes capacity for more critical loads, while outstanding energy savings can be achieved based on the AC-AC efficiency of up to 96.5% and 99% in ECO mode. In addition, RT Series 5-20kVA UPS is the first in the market that offers standard Li-ion external battery cabinets, which deliver better power density and sustainability. Along with the parallel capacity of up to four units, the new series is the ideal small power UPS for mission-critical applications, such as servers, data centers, telecommunications, and manufacturing.

Counseling support+84-979933470

T.A.T International Company Limited is an authorized Distributor of Delta Electronics

RT Series 5/6/8/10/15/20 kVA (new) - Amplon Family

 

Features and Benefits

Availability & Flexibility
 
True online double-conversion topology and zero transfer time to battery provides 24/7 full-time protection
Wide input voltage range allows the UPS to operate in harsh electrical environments and extends battery life
AC-start function allows the UPS to be switched on without connecting to a battery
Programmable load bank disconnects non-critical loads when a blackout occurs and reserves more battery power for critical loads
Up to four units parallel capacity allows redundancy and load expansion
Hot swappable batteries ensure continuous operation even when batteries are being replaced
VRLA and Li-ion External Battery Cabinet (EBC) are available for scalable runtime
Extended Runtime models support flexible battery quantity for battery investment optimization. And when one battery fails, it could be removed without replacing the entire battery string, reducing maintenance cost and efforts
The Power Distribution Box (PDB) and Maintenance Bypass Breaker (MBB), which are default to RT 5-10kVA Standard Runtime models, enable simple configuration
The Maintenance Bypass Breaker (MBB) is optional for easy UPS replacement without powering down critical systems
The rRPP (Rack Remote Power Panel), which can be integrated with standard server racks, simplifies power output distribution and power monitoring
Common battery configuration is supported in UPS parallel mode to save installation space and additional battery costs
 
 
  Efficiency & Reliability
 
Unity output power factor guarantees no de-rating with loads and provides permanent 100% kW
Best-in-class AC-AC efficiency of up to 96.5% and 99% in ECO mode lowers energy costs
Automatic fan speed control maximizes system efficiency and significantly reduces audible noise and prolongs battery life
Fan failure detection sends early warnings to facilitate predictive maintenance of UPS
 
 
  Manageability
 
Intelligent battery management to extend battery life and maximize battery performance. The battery aging detection monitors battery status for predictive maintenance, and the 3-stage charging mechanism keeps the battery from continuous float charging during the intermission stage to prolong battery life
Excellent local management through a user-friendly graphical and multi-lingual LCD display
Various types of communication interfaces, including USB, RS-232, and RS-485 ports, mini slot, REPO/ROO for remote management, and in-built dry contacts for monitoring and notification of system operation conditions
UPS management software such as ShutdownAgent and InfraSuite Device Manager allow users to monitor UPS status and protect critical devices

 

Applications:

 

For more information of Delta Electronics, please contact:

T.A.T International Company Limited – An authorized Distributor of Delta Electronics Vietnam

Email: sales@tatint.com / Tel: 0979 933 470

Runtime:

 

 

 

 

Standard Model

 

 

 

 

 

 

Power Rating

VRLA Battery

Run time at different load (mins)

25%

50%

75%

100%

5 kVA
(UPS502R2RT0B0B8)

Internal

35.6

15.6

8.9

5.6

External x 1

68.0

31.0

19.0

13.0

External x 2

106.0

51.0

32.0

22.6

External x 3

145.5

71.5

45.5

32.5

External x 4

185.0

91.5

59.0

42.5

   

 

 

 

5 kVA
(UPS502R2RT0B035)

External x 1

61.0

27.0

16.5

11.0

External x 2

96.0

45.5

28.0

19.5

External x 3

131.0

63.5

40.0

28.5

External x 4

166.5

82.0

52.5

37.5

6 kVA

Internal

24.3

9.6

5.6

3.1

External x 1

50.0

22.0

13.0

8.5

External x 2

79.5

37.0

22.5

15.5

External x 3

109.0

52.0

32.5

22.5

External x 4

137.0

67.0

42.5

30.0

   

 

 

 

8 kVA

Internal

36.3

15.6

9.3

5.1

External x 1

71.0

27.0

14.5

9.6

External x 2

119.0

49.5

27.5

17.5

External x 3

167.5

73.5

42.5

27.5

External x 4

217.0

98.0

58.0

39.0

10 kVA

Internal

30.2

11.9

6.2

3.7

External x 1

53.0

19.4

10.5

7.4

External x 2

91.0

36.0

19.5

12.5

External x 3

130.0

54.8

30.5

19.5

External x 4

170.0

74.0

42.5

28.0

   

 

 

 

Extended Model

   

 

 

 

Power Rating

VRLA Battery

Run time at different load (mins)

25%

50%

75%

100%

5 kVA

External x 1 (GES161B107035)

35.2

15.2

7.8

5.1

External x 2 (GES161B107035)

61.0

27.0

16.5

11.0

External x 3 (GES161B107035)

96.0

45.5

28.0

19.5

External x 4 (GES161B107035)

131.0

63.5

40.0

28.5

External x 1 (GES201B109035)

50.0

18.5

10.3

7.3

External x 2 (GES201B109035)

123.5

53.2

30.0

19.3

External x 3 (GES201B109035)

199.5

91.0

54.2

36.0

External x 4 (GES201B109035)

276.4

130.0

79.5

54.5

   

 

 

 

6 kVA

External x 1 (GES161B107035)

24.3

9.6

5.6

3.1

External x 2 (GES161B107035)

50.0

22.0

13.0

8.5

External x 3 (GES161B107035)

79.5

37.0

22.5

15.5

External x 4 (GES161B107035)

109.0

52.0

32.5

22.5

External x 1 (GES201B109035)

39.0

14.2

8.2

6.0

External x 2 (GES201B109035)

100.5

41.4

22.5

14.5

External x 3 (GES201B109035)

164.4

72.5

42.0

27.5

External x 4 (GES201B109035)

228.5

105.0

63.0

42.5

   

 

 

 

8 kVA

External x 1

36.3

15.6

9.3

5.1

External x 2

71.0

27.0

14.5

9.6

External x 3

119.0

49.5

27.5

17.5

External x 4

167.5

73.5

42.5

27.5

10 kVA

External x 1

30.2

11.9

6.2

3.7

External x 2

53.0

19.4

10.5

7.4

External x 3

91.0

36.0

19.5

12.5

External x 4

130.0

54.8

30.5

19.5

   

 

 

 

15 kVA

EBC: external battery cabinet

External x 1 set (2 EBC) (BBU201B109035)

39.3

16.8

10.0

6.8

External x 2 set (4 EBC) (BBU201B109035)

90.5

41.1

25.0

17.2

External x 3 set (6 EBC) (BBU201B109035)

143.1

67.4

41.9

29.2

External x 4 set (8 EBC) (BBU201B109035)

196.1

94.3

59.7

42.1

External x 1 set (2 EBC) (GES161B107035)

16.4

7.1

4.0

2.3

External x 2 set (4 EBC) (GES161B107035)

39.3

17.6

10.6

7.4

External x 3 set (6 EBC) (GES161B107035)

63.5

29.5

17.9

12.5

External x 4 set (8 EBC) (GES161B107035)

88.2

41.9

25.8

18.2

Li-ion battery :
External x 1 set (2 EBC) (GES021B704035 + 099114191A)

24.0

10.8

8.1

5.8

   

 

 

 

20 kVA

EBC: external battery cabinet

External x 1 set (2 EBC) (BBU201B109035)

27.5

11.5

6.8

4.4

External x 2 set (4 EBC) (BBU201B109035)

65.1

28.7

17.2

11.8

External x 3 set (6 EBC) (BBU201B109035)

104.4

47.8

29.2

20.2

External x 4 set (8 EBC) (BBU201B109035)

144.3

67.7

42.1

29.3

External x 1 set (2 EBC) (GES161B107035)

11.6

4.8

2.3

1.3

External x 2 set (4 EBC) (GES161B107035)

28.3

12.3

7.4

4.6

External x 3 set (6 EBC) (GES161B107035)

46.4

20.7

12.5

8.6

External x 4 set (8 EBC) (GES161B107035)

65.1

29.8

18.2

12.5

Li-ion battery :
External x 1 set (2 EBC) (GES021B704035 + 099114191A)

18.6

8.9

5.8

3.6

   

 

Rear Views


TAGS:


The Same Products