ZGLJ-B3 Multi-channel Lightning Monitor of the Wind Power System
Product code :
The system can monitor the lightning current information of wind turbine blades subjected to lightning strikes in real time and accurately.
Lightning threatens the safe operation of wind turbines. Therefore, we need to accurately grasp the time, frequency and lightning current characteristics of wind turbines subjected to lightning strikes, for easy evaluation of the effects of lightning protection facilities, and providing the basis for design, reconstruction and insurance claims of lightning protection in the area, to ensure the safe operation of wind turbines.
The system consists of the lightning current sensor installed in the blades and hubs, lightning monitor, and lightning data management software for the monitoring center.
ZGLJ-B3 Multi-channel Lightning Monitor of the Wind Power System
General
The system can monitor the lightning current information of wind turbine blades subjected to lightning strikes in real time and accurately.
Lightning threatens the safe operation of wind turbines. Therefore, we need to accurately grasp the time, frequency and lightning current characteristics of wind turbines subjected to lightning strikes, for easy evaluation of the effects of lightning protection facilities, and providing the basis for design, reconstruction and insurance claims of lightning protection in the area, to ensure the safe operation of wind turbines.
The system consists of the lightning current sensor installed in the blades and hubs, lightning monitor, and lightning data management software for the monitoring center.
Standards Complied
Q/75875187-9·7 - 2016 Lightning monitoring system
GB/T 3783-2008 General specification for low-voltage apparatus in ships
GB/T 3797-2016 Electrical control assemblies
Product Configuration (Standard Configuration)
Name | Quantity | Unit | Remarks |
ZGLJ-B3 lightning monitor | 1 | Set | |
Lightning current sensor | 3 | Set | |
Lightning data management software | 1 | Set | For one project, a set of software programs is equipped. |
Performance Index
Item | Index |
Monitored object | Lightning occurrence time, peak value, polarity, number of times, charge amount, specific energy, and steep-wave coefficient |
Monitoring range of lightning peaks | ±5 kA~±250 kA |
Measuring error | ≤±100 kA: ≤±10 % |
>±100 kA: ≤± 5% | |
Error in the front time and time to half value | ≤±10% |
Sensor frequency response | 1Hz~1 MHz |
Sampling frequency | 10 MHz |
Waveform acquisition length | 1 s |
Storage capacity | ≥8 GB |
Communication interface | RS485/CAN/Ethernet |
Communication protocol | Profibus DP/Modbus RTU/ Modbus TCP |
Waterproofing grade | IP65 |
Overall power consumption | ≤12 W |