ZGGS40-890PV Modular Power Supply SPD
Product code :
The ZGGS40-890PV Modular Power Supply SPD consists of the MOV, flame retardant housing and metal components, characterized by fire-retardant, over-current & overheat protection and remote signaling alarm. It is installed on the PCB board, mainly used for secondary and tertiary surge protection in low voltage AC/DC power supply and distribution system and electrical equipment.
ZGGS40-890PV Modular Power Supply SPD
General
The ZGGS40-890PV Modular Power Supply SPD consists of the MOV, flame retardant housing and metal components, characterized by fire-retardant, over-current & overheat protection and remote signaling alarm. It is installed on the PCB board, mainly used for secondary and tertiary surge protection in low voltage AC/DC power supply and distribution system and electrical equipment.
Standards Complied
IEC 61643-11:2011 Low-voltage surge protective devices - Part 11: Surge protective devices connected to
low-voltage power systems – Requirements and tests
EN 61643-11:2012 Low-voltage surge protective devices - Part 11: Surge protective devices connected to
low-voltage power systems – Requirements and tests
UL1449 Ed.4 Safety standard for Surge Protective Devices
EN 50539-11: 2013 Low-voltage surge protective devices -Surge protective devices for specific application
including d.c. -Part 11: Requirements and tests for SPDs in photovoltaic applications
GB/T 18802.31-2016 Low-voltage surge protective devices Special application (including DC) surge protector (SPD)——Part 31: Surge protective devices (SPD) for photovoltaic systems - Performance requirements and test methods
Technical parameters
Model | ZGGS40-890PV |
SPD according to IEC 61643-11:2011 | Class Ⅱ |
SPD according to EN 61643-11:2012 | Type 2 |
Max. continuous operating voltage Uc | 680V AC |
Nominal discharge current In(8/20μs) | 20kA |
Max. discharge current Imax(8/20μs) | 40kA |
Voltage protection level Up | 2.9kV |
Rated short circuit current ISCCR | 600A |
Low voltage system TOV UT | 915V AC/5s |
Low voltage system TOV characteristic | Withstand |
Connection mode | PCB-board in parallel |
Location of installation | Indoors |
Application system | TN;TT、IT:L-N |
Degree protection | IP20 |
SPD according to EN 50539-11:2013 GB/T 18802.31-2016 |
Type 2 |
Max. continuous operating voltage Ucpv | 890V DC |
Rated short circuit current Iscpv | 50A |
Nominal discharge current In (8/20μs) | 20kA |
Max. discharge current Imax (8/20μs) | 40kA |
Voltage protection level Up | 2.9kV |
Protection mode | + — -, +/- —PE |
Application system | Photovoltaic system |
Configuration
Flame retardant degree:UL94V-0